EUResearch & Innovation, Research Fund for Coal and Steel                                          frame                            

FISHWALL
FIre and Seismic performances of Hybrid fire WALLs in case of single-storey industrial and commercial steel buildings
     

 

1twofirewall42  5

 

Projekt objective
Fire walls are commonly employed inside single-storey buildings and if the structures are in steel they can be left unprotected. However, questions are being very often raised in Europe about the appropriateness of widely used fire wall solutions with unprotected steel structures, which have also to comply with seismic safety requirement if they are used in seismic areas. The current project aims to overcome the present lack of knowledge, through both experimental and numerical investigations and to develop an innovative hybrid steel-based fire wall solution using sandwich panels for single-storey buildings with unprotected steel structures as well as design guidance.
Cíl projektu
iožární stěny se využívají uvnitř jednopodlažních budov. Ocelové konstrukce mohou být ponechány bez požární ochrany. V Evropě  vyvstávají otázky o vhodnosti široce používaných řešení protipožárních stěn s nechráněnými ocelovými konstrukcemi, které musí splňovat požadavky na seismickou bezpečnost, pokud jsou použity v seismických oblastech. Projekt řeší nedostatek znalostí o stěnách experimentálními i numerickými modely a vyvojem hybridního řešení požárních stěn se sendvičovými panely pro jednopodlažní budovy s nechráněnými ocelovými konstrukcemi. Pro návrh stěn budou připraveny podklady a postup návrhu.